It’s been an intense summer across the Northeast. We’ve already seen afternoon temperatures creeping toward triple digits this month, and the humidity hasn’t made things any easier. In conditions like these, a cooling system that stops working isn’t just an inconvenience; it can be a genuine safety issue.
The Needham Oil Complete Heating & Cooling team has been working around the clock to restore comfort for our customers, and we’re always here when you need us. But before you pick up the phone, we encourage you to run through these troubleshooting steps. One of them could get your system running again quickly and save you the cost of a service call.
A simple settings issue can mimic a serious system failure. Make sure your thermostat is set to “cool” rather than “fan” or “heat,” and that the target temperature is set at least a few degrees below the current indoor temperature. If the system doesn’t have a reason to kick on, it won’t, regardless of how warm the house feels.
It sounds basic, but a tripped circuit breaker or a switch left in the wrong position is the cause of more “broken” A/C calls than you’d expect. Head to your electrical panel and check whether any breakers have tripped. Also, confirm that all power switches connected to your HVAC equipment are in the on position.
A clogged air filter is one of the most common reasons a central A/C system underperforms. When the filter fills up with dust, debris, and pet hair, airflow gets restricted, and your system works harder for less output. Find the filter near your indoor air handler or furnace, and hold it up to the light. If little or no light passes through, it’s overdue for a replacement. A fresh filter every one to three months should keep your airflow strong and your system running efficiently.
Your outdoor condenser needs space to breathe. Grass clippings, leaves, weeds, and dirt buildup around the unit can choke airflow and reduce cooling capacity. Shut off power to the condenser, then clear at least two feet of space on all sides. You can gently rinse the exterior coils with a garden hose or use a soft-brush vacuum attachment to remove debris, but please avoid high-pressure water, which can bend the delicate aluminum fins.
If your indoor evaporator coil freezes over, cool air stops flowing, even though the system appears to be running. Warning signs include weak airflow from your vents, air that feels warm rather than cool, frost or ice on the refrigerant lines, and pooling water near the indoor unit as ice melts. If you suspect a frozen coil, shut the system off immediately and call a professional. Running a frozen system risks serious damage to the compressor.
If your system is running but struggling to keep up, with long cycles, poor cooling, and rising energy bills, a refrigerant leak may be the culprit. Refrigerant can’t be topped off like motor oil; a certified technician needs to locate and repair the leak before recharging the system. This is not a DIY repair, and it’s important to address it promptly.
For homeowners in Westwood and throughout Middlesex and Norfolk Counties, the best way to avoid a midsummer cooling breakdown is to stay ahead of it. Our plans include annual professional maintenance, priority service, a discount on repairs and diagnostic fees, and more!
Contact Needham Oil Complete today to enroll in a service plan or to schedule a repair.